<?XML Version="1.0">
<nidocument>
<nicomment>
LabVIEW error file
</nicomment>
<nierror code="-27026">
NI-Tuner:  The specified ready pulse length is out of range.
</nierror>
<nierror code="-27025">
NI-Tuner:  Signal polarities may only be active high or active low.
</nierror>
<nierror code="-27024">
NI-Tuner:  An unknown signal type was specified.
</nierror>
<nierror code="-27023">
NI-Tuner:  An unknown signal path was specified.
</nierror>
<nierror code="-27021">
NI-Tuner:  The requested attribute is not used this function.
</nierror>
<nierror code="-27020">
NI-Tuner:  The FPGA download failed.
</nierror>
<nierror code="-27019">
NI-Tuner:  The CPLD rejected the FPGA download initialization.
</nierror>
<nierror code="-27018">
NI-Tuner:  One of the parameters was NULL, making it unusable.  Allocate memory for the parameter.
</nierror>
<nierror code="-27017">
NI-Tuner:  This setting would attempt to send signals in two different directions at the same time.
</nierror>
<nierror code="-27016">
NI-Tuner:  Unknown PLL.
</nierror>
<nierror code="-27015">
NI-Tuner:  Invalid RTSI setting.
</nierror>
<nierror code="-27014">
NI-Tuner:  Initialize the PXI-5600 before calling this function.
</nierror>
<nierror code="-27013">
NI-Tuner:  Reset the PXI-5600 before calling this function.
</nierror>
<nierror code="-27012">
NI-Tuner:  Value is out of range.
</nierror>
<nierror code="-27011">
NI-Tuner:  The span must be between 0 and 20 MHz inclusively.
</nierror>
<nierror code="-27010">
NI-Tuner:  Array size must be greater than 0.
</nierror>
<nierror code="-27008">
NI-Tuner:  Unable to write data to the EEPROM: verification of written data failed.
</nierror>
<nierror code="-27007">
NI-Tuner:  Unable to obtain a direct link to the device's registers.
</nierror>
<nierror code="-27006">
NI-Tuner:  DMA transfer was unsuccessful: it was stuck in an infinite loop.
</nierror>
<nierror code="-27005">
NI-Tuner:  The attenuation relay is busy.  This is a hardware problem.
</nierror>
<nierror code="-27004">
NI-Tuner:  The downconverter is busy.  This indicates that its internal state machine may be locked up.
</nierror>
<nierror code="-27003">
NI-Tuner:  Frequency counter timed out.
</nierror>
<nierror code="-27002">
NI-Tuner:  Unable to allocate memory.
</nierror>
<nierror code="-27001">
NI-Tuner:  A bit size too large was specified for the serial chain.
</nierror>
<nierror code="27009">
NI-Tuner:  Unable to load calibration settings.
</nierror>
<nierror code="27022">
NI-Tuner:  Requested attenuation settings have been coerced to fit within the 0 to 80 dB range.
</nierror>
<nierror code="27027">
NI-Tuner:  Specified mixer level is out of range (must be no more than 0 dB).
</nierror>
<nierror code="27028">
NI-Tuner:  Specified reference level is out of range (must be within 50 dB higher than the mixer level).
</nierror>
</nidocument>